Reset Search
 

 

Article

S-Series: Error message logged - <3>Dune[6.dTcmTask]Petra[0] Received Interrupt PB_IQM_ECC_INTR_ERR instance 0, count 4, value= 0x1

« Go Back

Information

 
TitleS-Series: Error message logged - <3>Dune[6.dTcmTask]Petra[0] Received Interrupt PB_IQM_ECC_INTR_ERR instance 0, count 4, value= 0x1
Symptoms
  • Unit has not reset nor generated any core files
  • Chassis function not reported as being affected
  • S-Series: Error message logged
<3>Dune[6.dTcmTask]Petra[0] Received Interrupt PB_IQM_ECC_INTR_ERR instance 0, count 4, value= 0x1
  • Debug message log shows the following:
<3>System[6]This device has encountered a hardware failure. Petra[0] ex 
ceeded maximum soft resets Please contact Support for a possible repair 
/replacement.

 
Environment
  • k-series
  • S-Series
  • All Firmware
  • SK8008-1224-F8
  • SK8208-0808-F8
Cause
Faulty hardware
Resolution
Additional notes