Reset Search
 

 

Article

S-Series Logging Error about GBIC tNimIntr]Unable to perform read data access to pluggable

« Go Back

Information

 
TitleS-Series Logging Error about GBIC tNimIntr]Unable to perform read data access to pluggable
Symptoms
  • Error message:
<163>Jan 20 19:12:27 10.0.5.42 NIM[5.tNimIntr]Unable to perform read data access to pluggable module installed in tg.5.20. The system is unable to perform proper configuration which may result in unreliable port operation. Please insure this pluggable is fully inserted. If problem repeats replace the pluggable.
  • Move GBIC to a different port message stops
  • Move GBIC to original slot and problem never returns
Environment
S-Series
Cause
Poor connection on GBIC to slot
Resolution

  • Ensure GBIC is seated correctly
  • If issue persists, try replacing GBIC
Additional notes
If issue persist, contact the GTAC for immediate technical assistance.