S-Series Option Module ports showing "Other Fault" for POE status - base blade shows normal status

« Go Back

Information

 
TitleS-Series Option Module ports showing "Other Fault" for POE status - base blade shows normal status
Symptoms
S-Series Option Module ports showing "Other Fault" for POE status, while base blade showing as searching or delivering power:
S-Chassis-> show port inlinepower
Port     Type          Oper             Admin  Priority Class Power Power PD     Power  Power 
         (truncated)   Status           Status                Limit Usage Type   Capab- Capab 
                                                              (mW)  (mW)         ility  Select
-------- ------------- ---------------- ------ -------- ----- ----- ----- ------ ------ ------
ge.1.48                delivering power auto   low      2     15400 2800  8023   8023at 8023af  (Base Blade port)
ge.1.101               other fault      auto   low      0     15400 0     other  8023at 8023af  (Option Module Port)
 
Environment
  • S-Series
  • All firmware versions
  • POE status showing fault
Cause
POE Power Header needs to be installed between base blade and option module to provide POE to option module RJ-45 ports
Resolution
Verify POE Header is installed between base blade (Fabric module or I/O Module) and the option modules as seen here:

POE Power Header