Symptoms
  • ACL configuration changes after reboot or blade failover
  • This only happens if there is a somehow different config on different blades ( example replacing a bonded unit )
  • Should not be an issue under normal circumstances 
Environment
  • S-Series
  • Discovered on Firmware 8.42.04 
Cause
There is a bug in ACL distribution/syncing between blades. 

When there are different settings between blades, the setting on the distribution server master blade is correctly used.  However the nonvol on the slave blades is not modified to this value, leading to the potential "config change" should one of them become master in future.( for example after reboot or blade failure )
Resolution
Under investigation 