S-Series reset with "Fuji FAB SUB 2" error message in logs

« Go Back

Information

 
TitleS-Series reset with "Fuji FAB SUB 2" error message in logs
Symptoms
  • S-Series blade reset
  • A message similar to the following is seen:
==============================================================================
Message 6/248 Syslog Message 08.21.02.0001 12/04/2014 17:59:34

<3>Fuji[3.tNimIntr]Fuji FAB SUB 2 intr: Fuji=3, Adr=6, Reg=0x00000008 (S
PAUI intr: Adr=0, Reg=0x00008017)

==============================================================================

 
Environment
  • S-Series
  • All firmware versions
Cause
Faulty hardware component
Resolution
  • If the Fuji chip is on an option module, replace the option module and parent blade as a pair.
  • If the Fuji chip is on the parent blade, replace only the parent blade.