Reset Search
 

 

Article

SNMP TOOBIG Errors Seen When Polling EXOS Switches

« Go Back

Information

 
TitleSNMP TOOBIG Errors Seen When Polling EXOS Switches
Symptoms
SNMP TOOBIG errors seen on SNMP Server after polling attempts to EXOS switches.
Environment
  • EXOS All
  • SNMP v2/v3
  • Extreme Management
Cause
EXOS responses to GetBulk requests and IP fragmentation by default functions to be compatible with the legacy NMS Ridgeline.
Resolution
To make the switch operate in the standards compliant mode, use the following commands
configure snmp compatibility get-bulk reply-too-big-action standard
configure snmp compatibility ip-fragmentation allow
Commands available in EXOS version 15.5 and later

 
Additional notes
To verify settings:
show management

 