SNMP timeout and slow response after upgrade on X440 stack of 8 units

« Go Back

Information

 
TitleSNMP timeout and slow response after upgrade on X440 stack of 8 units
Symptoms
  • SNMP timeouts are occurring following an upgrade
  • Delayed SNMP reply from X440 to NMS
  • All traffic, including Telnet and pings are unaffected
  • Only occuring on X440 stacks with 5 or more units
  • Stack upgraded from 15.5.3.4 patch  to 16.1.2.14-1-1
Environment
  • Summit X440-48p
  • EXOS 16.1.2.14-patch 1-1
  • NetSight NMS
Cause
SNMP times out when saving an eight-node stack od Summit X440 series switches
Resolution
Fixed in EXOS GA releases
16.1.4.2-patch1-7 and 16.2.2.4
 
Additional notes

Feedback

 

Was this article helpful?


   