Reset Search
 

 

Article

SecureStack B5 upgraded to 681080005 resulting in failed Sha/AES SNMPv3 auth in NMS

« Go Back

Information

 
TitleSecureStack B5 upgraded to 681080005 resulting in failed Sha/AES SNMPv3 auth in NMS
Symptoms
  • Lost SNMP contact
  • Device currently in a 2 unit stack was formally in a 5 unit stack
Environment
  • B5G124-48 (two units stacked)
  • Firmware 6.81.08.0005
  • Stack manager previously was in larger stack
Cause
Code was upgrade before issue was seen.  Suspect confusion with the stack manager.
Resolution
  • Reset the units in the stack to factory defaults
  • Rebuild the stack
  • Put configuration onto stack
Additional notes