TitleSecureStack spontaneous reset "edb_bxs.c(1314) %% Last switch reset caused by Fault(0x00000300)"
Symptoms
  • Spontaneous reset
  • Loss of communication
Environment
  • SecureStack
  • Firmware 06.81.03.xx and earlier
Cause
Reset in the SNMP Task
edb_bxs.c(1314) 780 %% Last switch reset caused by Fault(0x00000300) SRR0(0x009A4068) SRR1(0x0000B032) DMISS(0x2444F5C8) IMISS(0x00000000) DAR(0x00000000) DSISR(0x0A000000)

 
Resolution
  • Upgrade to 06.81.04.xx firmware code per the following release note:
19332 Corrected a reset issue in the SNMP Task that resulted in the message “edb_bxs.c(1314) 73 %% Last
switch reset caused by Fault(0x00000300) SRR0(0x01104270) ESR(0x00800000) MSR(0x00000200)
DEAR(0x0000000C) IMISS(0x01104270)”.
  • This fix is listed in 06.81.03.xx, but this image was pulled from our website, so upgrade to 06.81.04.xx will contain fix