Reset Search
 

 

Article

"Show fans" outputs displays fan status as Empty

« Go Back

Information

 
Title"Show fans" outputs displays fan status as Empty
Symptoms
When you run the command "Show Fans" the output displays the fan status as empty as below.

X440-24t-10G.1 # sh fans
FanTray information:
State: Operational
NumFan: 2
Fan-1: Empty at 11000 RPM 
Fan-2: Empty at 11000 RPM



 
Environment
  • EXOS 15.6.1
  • Summit X440
Cause
The is caused by a software issue and can be tracked via CR xos0058889.

 
Resolution
Upgrade the device to a fixed release.   CR  xos0058889 is resolved in the following EXOS releases:
  • 16.1.1.4
  • 15.7.1.4
  • 15.6.2.12