Reset Search
 

 

Article

The status LED on I/O module got stuck in BDX8 platforms

« Go Back

Information

 
TitleThe status LED on I/O module got stuck in BDX8 platforms
Symptoms
When MM-A is uninstalled, the status LED of I/O module is suddenly stopped.
These issues occur only when using the MM-A with Master node. The issue is not seen when when we are removing MM-B with master or backup.
Environment
  • BDX8
  • 16.1.4.2-patch1-3
Cause
This is caused by the software issue and can be tracked via CR#xos006764
Resolution
Upgrade to EXOS where CR#xos0067644 is fixed
Additional notes

Feedback

 

Was this article helpful?


   

Feedback

Please tell us how we can make this article more useful.

Characters Remaining: 255