When MGBIC-02 is installed into a previously disabled port it will not go operational when enabled

« Go Back

Information

 
TitleWhen MGBIC-02 is installed into a previously disabled port it will not go operational when enabled
Symptoms
  • When MGBIC-02 is installed into a previously disabled port it will not go operational when enabled
  • The port status is admin status UP but Operational status still DOWN
Environment
  • S-Series
  • 7100-Series 
  • Firmware 8.21.xx
  • Firmware 8.22.xx
  • Firmware 8.32.xx
  • Firmware 8.42.xx
  • MGBIC-02
Cause
Firmware Issue.

Here is the process to recreate the issue: 
  1. Disable the port ( set port disable ge.1.34 )
  2. Insert the MGBIC-02  ( note that the type is now correctly 1000-t RJ45
  3. Connect the UTP cable 
  4. Enable the port ( set port enable ge.1.34 )
- Note that now the port status is admin status UP but still Operational status still DOWN                                                                        

                                                                                                 
Resolution
Upgrade to firmware 8.62.01

Workaround :

To restore connectivity remove the MGBIC ( while the port is enabled ) and re-insert it.     

 
Additional notes