Reset Search
 

 

Article

When "rate-limit input unknown-unicast" is used under a VPLS instance, if traffic stops and more than 30 seconds passes before "show rate-limit counters" is checked, drop counters show as reset to 0.

« Go Back

Information

 
TitleWhen "rate-limit input unknown-unicast" is used under a VPLS instance, if traffic stops and more than 30 seconds passes before "show rate-limit counters" is checked, drop counters show as reset to 0.
Symptoms
When "rate-limit input unknown-unicast" is used under a VPLS instance, if traffic stops and more than 30 seconds passes before "show rate-limit counters" is checked, drop counters show as reset to 0.
Environment
  • NetIron MLX
  • NI 6.2.00ca
  • MPLS
  • VPLS
  • "rate-limit input unknown-unicast" configured under a VPLS
Cause
Counters used for accumulation of statistics are not correctly initialized. This issue is effectively similar to DEFECT000639485 but applies specifically to "rate-limit input unknown-unicast" configured under a VPLS.
Resolution
This issue is resolved in NI 6.2.00cc as Defect ID NI-17641.