Reset Search
 

 

Article

Сablediag.py is not working on X440-G2-48p/t platforms

« Go Back

Information

 
TitleСablediag.py is not working on X440-G2-48p/t platforms
Symptoms
Cablediag application is not working on X440-G2-48p/t platforms.
Even though cable is present cable diagnostics output shows as "OPEN", the same as is on the following example.
X440-G2-48p-10GE4.1 # run script cablediag.py -p 11
cablediag: 1.1.0.2


+++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
+                             C A U T I O N                             +
+   cablediag will momentarily interfere with traffic on active ports   +
+                               Ports: 11                               +
+++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
Do you want to continue cable diagnostics? [y/N]: y
Collecting port cable diagnostic information may take a moment...
port 11: cable (4 pairs, length +/- 10 meters)
        pair A Open, length 0 meters
        pair B Open, length 0 meters
        pair C Open, length 0 meters
        pair D Open, length 0 meters


 
Environment
  • X440-G2-48t-10GE4
  • X440-G2-48p-10GE4
  • X440-G2-48t-10GE4-DC
  • EXOS 22.2.1.5-patch1-4
  • EXOS 16.2.3.5-patch1-3
Cause
The issue is documented under CR xos0068490.
Resolution
Upgrade to an EXOS version which contains the fix for xos0068490.

Target Releases:
  • EXOS 22.3.1
  • EXOS 16.2.3-GA-Aug17
  • EXOS 21.1.4-GA-Sep17
Additional notes

Feedback

 

Was this article helpful?


   

Feedback

Please tell us how we can make this article more useful.

Characters Remaining: 255