TitleReboot due to memory depletion of process CLImaster
Symptoms
The switch reboots due to a memory depletion of process CLImaster when running EXOS 15.7.1 or EXOS 16.1.1
exact error: System memory depleted

 
Environment
  • EXOS 15.7.1
  • EXOS 16.1.1
  • using Chalet (the web-interface)
Cause

This is caused due to a bug with the implementation of certain methods in python. Chalet (the web-interface from EXOS) uses these methods heavily and therefor create this memory leak.
If the web-interface of EXOS is not used, then this article is most likely not applicable.

Resolution
Upgrade to a version that includes the fix for xos0062016:

These are the following versions :
  • EXOS 15.7.2 or higher
  • EXOS 16.1.2 or higher
  • EXOS 16.2.1 or higher
  • EXOS 21.1.1 or higher
Additional notes